Product Name :
Mouse anti Human CD4

Description :
| Clone 7E14 | Isotype IgG1 | Product Type Single-Color Reagent | Units 100 µg | Host Mouse | Species Reactivity Human | Application Flow Cytometry

Background :
Immunogen: Derived from the hybridization of mouse NS-1 myeloma cells with spleen cells from BALB/c mice immunized with human perherial blood T lymphocytes.

Source :
Identification of human helper/inducer T cells expressing the 60,000 M.W. surface antigen (HLA class II reactive). CD4 is present in low density on monocytes. Synonyms: T-cell surface glycoprotein CD4; T-cell surface antigen T4/Leu-3 <

Product :
Product Form: Unconjugated Formulation: Provided as solution in phosphate buffered saline with 0.08% sodium azide Purification Method: Protein A/G Chromatography Concentration: See vial for concentration

Specificity :

Applications :
PBMC: Add10 µl of MAB/10 PBMC in 100 µl PBS. Mix gently and incubate for 15 minutes at 2to 8°C. Wash twice with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze. WHOLE BLOOD: Add10 µl of MAB/100 µl of whole blood. Mix gently and incubate for 15 minutes at room temperature 20°C. Lyse the whole blood. Wash once with PBS and analyze or fix with 0.5% v/v of paraformaldehyde in PBS and analyze. See instrument manufacturer’s instructions for Lysed Whole Blood and Immunofluorescence analysis with a flow cytometer or microscope. ALLOPHYCOCYANIN: (APC) conjugates are analyzed in multi-color flow cytometry with instruments equipped with a second laser and proper filters. Laser excitation is at 633 nm with a Helium Neon (HeNe) laser or a 600-640 nm (633 nm) range for a Dye laser. Peak fluorescence emission is at 660 nm. RPE-Cy-5 +: Excites at 488nm and emits at 670nm. Store protected from light. Functional Analysis: Flow Cytometry Staining

Storage :
Product should be stored at -20°C. Aliquot to avoid freeze/thaw cycles Product Stability: See expiration date on vial Shipping Conditions: Room Temperature

Caution :
This product is intended FOR RESEARCH USE ONLY, and FOR TESTS IN VITRO, not for use in diagnostic or therapeutic procedures involving humans or animals. It may contain hazardous ingredients. Please refer to the Safety Data Sheets (SDS) for additional information and proper handling procedures. Dispose product remainders according to local regulations.This datasheet is as accurate as reasonably achievable, but our company accepts no liability for any inaccuracies or omissions in this information.

References :
1. Thymus Dependent Membrane Antigens in Man: Inhibition of Cell-Mediated Lympholysis by Monoclonal Antibodies to the TH-2 Antigen. Evans,R.L., Wall,D.W., Platsoucas,C.D., Siegal,F.P., Fikrig,S.M., Testa,C.M, and Good,R.A. Proc. Nat. Acad. Sci. 78,544,1981. 2. Novel Immunoregulatory Functions of Phenotypically Distinct Subpopulations of CD4+ cells in the Human Neonate. Clement,L.T., Vink,P.E., Bradley,G.E. J. Immunology 145(1):102-8,1990 . 3. Antigen Presentation by the CD4 Positive Monocyte Subset. Szabo,G., Miller,C.L., Kodys,K., J. Leukoc. Biol. 47(2): 111-20,1990. 4. Human Immunodeficiency Virus Infection is Efficiently Mediated by a Glycolipid-Anchored form of CD4. Diamond,D.C., Finberg,R., Chaudhuri,S., Sleckman,B.P., Burakoff,S.J., Proc. Natl. Acad. Sci. 87(13):5001-5,1990. 5. Development Regulation of the Intrathymic T cell Precursor Population. Adkins,B., J. Immunol. 146(5):1387-93,1991. 6. Induction of CD4 and Susceptibility to HIV-1 Infection in Human CD8+ T Lymphocytes by Human Herpesvirus 6. Lusso,P., De Maria,A., Malnati,M., Lori,F., DeRocco,S.E., Baseler,M., Gallo,R.C., Nat. 349(6309):533-5,1991. 7. Immunofluorescence Measurement in a Flow Cytometer using Low-Power Helium Neon Laser Excitation. Shapiro, H.M, Glazer, A.N., Christenson, L., Williams, J.M., and Strom, T. B. Cytometry 4,276, 1983. 8. Comparison of Helium Neon and Dye lasers for Excitation of Allophycocyanin. Loken, M.R., Kiej, J.F. and Kelly, K.,A. Cytometry 8, 96, 1987. Cy-5 + Portions of this product is manufactured under license from Carnegie Mellon University, U.S. Patent Number 5,268,486. Product Specific References: 1. Gardner, J.P. et al. ‘Robust, but transient expression of adeno-associated virus-transduced genes during human t lymphopoisis.’ Blood, 1997, 90, 4854-4864.

Antibodies are immunoglobulins secreted by effector lymphoid B cells into the bloodstream. Antibodies consist of two light peptide chains and two heavy peptide chains that are linked to each other by disulfide bonds to form a “Y” shaped structure. Both tips of the “Y” structure contain binding sites for a specific antigen. Antibodies are commonly used in medical research, pharmacological research, laboratory research, and health and epidemiological research. They play an important role in hot research areas such as targeted drug development, in vitro diagnostic assays, characterization of signaling pathways, detection of protein expression levels, and identification of candidate biomarkers.
Related websites: https://www.medchemexpress.com/antibodies.html
Popular product recommendations:
Ubiquitin Antibody (YA022)
STAT4 Antibody
CYP7A1 Antibody: CYP7A1 Antibody is an unconjugated, approximately 55 kDa, rabbit-derived, anti-CYP7A1 polyclonal antibody. CYP7A1 Antibody can be used for: WB, ELISA, IHC-P, IHC-F, ICC, IF, expriments in human, mouse background without labeling.